In GVRP Configuration function folder, there are three functions supported,
including GVRP Config, GVRP Counter and GVRP Group explained below.
Function name: GVRP Config
F
unction Description: In the function of GVRP Config, it is used to confi-
gure each port's GVRP operation mode, in which there are seven parame-
ters needed to be configured described below.
Parameter Description:
GVRP State Setting: This function is simply to let you enable or disable
GVRP function. You can pull down the list and click the <Downward>
arrow key to choose "Enable" or "Disable". Then, click the <Apply>
button, the system will take effect immediately.
Join Time:
Used to declare the Join Time in unit of centisecond. Valid time range:
20 –100 centisecond, Default: 20 centisecond.
Leave Time:
Used to declare the Leave Time in unit of centisecond. Valid time
range: 60 –300 centisecond, Default: 60 centisecond.
Leave All Time: A time period for announcement that all registered
device is going to be de-registered. If someone still issues a new join,
then a registration will be kept in the switch. Valid range: 1000-5000
unit time, Default: 1000 unit time.