Lancom ES-2126+ Manual page 55

Hide thumbs Also See for ES-2126+:
Table of Contents

Advertisement

LANCOM ES-2126+ und LANCOM ES-2126P
Chapter 4: Operation of Web- based Management
54
Port No: Port number.
Port On: Shows whether the port is supplying the power to the PD or
not.
AC Disconnect Port Off: Port is turned off due to the AC Disconnect
function.
DC Disconnect Port Off: Port is turned off due to the DC Disconnect
function.
Overload Port Off: The switch will stop supplying the power to the port
due to the power required by the PD that is linked to the port on the
switch excesses the Class setting of the PD.
Short Circuit Port Off: The switch will stop supplying the power to the
port if it detects that the PD linked to the port is short circuit.
Over Temp. Protection: The port of the switch will be disabled due to
fast transient rise in temperature to 240
o
to 200
C.
Power Management Port Off: Due to total power required by all PDs
linked to the switch excesses the power limit, so the switch stops sup-
plying the power to this port after referring to the information of the
priority.
Function name: PoE Configuration
Function Description: In PoE Port Management function, user can confi-
gure the settings about PoE.
The switch complies with IEEE 802.3af protocol and be capable of detec-
ting automatically that whether the device linked to the port on the switch
is PD (Powered Device) or not. The switch also manage the power supple-
ment based on the Class of the PD, and it will stop supplying the power
o
C or slow rise in temperature