Starkey Mode - Sokkia im-101 Operator's Manual

Im-100 series intelligence measurement station
Table of Contents

Advertisement

(7) Laser-pointer/Guide light display
 Selecting Laser-pointer/Guide light: "33.7 Instrument Conditions - Instrument", Switching Laser-pointer/
Guide light ON/OFF: "5.1 Basic Key Operation"
:Laser-pointer is selected and ON
:Guide light is selected and ON
(8) Bluetooth communication status
:Connection established
(flashing): Connecting
(flashing): Waiting
(flashing):Disconnecting
:
Bluetooth device is OFF
(9) Appears when laser beam is emitted for distance measurement
(10) Input mode
: Inputting capital letters and figures.
A
: Inputting small letters and figures.
a
: Inputting numbers.
1
5.3

Starkey Mode

Pressing the Starkey {
In the Starkey mode, you can change the setting commonly used for measuring.
T i l t c r n
C o n t r a s t
R e t i c l e l e v : 3
R e f l e c t o r
Ye s ( H , V )
The following operations and settings can be made in the Starkey mode
1. Turning ON/OFF tilt angle correction
2. Adjusting the display unit's contrast (Steps 0~15)
3. Adjusting reticle illmination level (Steps 0~5)
4. Switching the target type
5. Turning ON/OFF laser plummet (for the instrument with the laser centering function)
6. Setting for press and hold the illmination key
7. Turning ON/OFF laser pointer
8. Turning ON/OFF guide light
* The Starkey mode can be called only from the OBS mode.
} displays the Starkey menu.
:
Ye s ( H , V )
: 1 0
: P r i s m
Ye s ( V ) N o
L a s e r p l u m :
O f f
L a s e r l e v.
: 3
I l l u m . h o l d
: L a s e r
L - p o i n t e r
: O f f
O f f
O n
20
5. BASIC OPERATION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Im-102Im-105Im-103

Table of Contents