• When [MOVE] is pressed, the last target measured
becomes the new starting position to perform missing line
measurement of the next target.
"21.2 Changing the Starting Point"
5. Press {ESC} to end missing line measurement.
PROCEDURE Calculating from input coordinates
1. In the third page of OBS mode screen, press [MLM], then
select "MLM".
2. Press [COORD] on the second page.
3. Input coordinates for the 1st target and press [OK].
• When you wish to read in and set coordinate data from
memory, press [LOAD].
 "13.1 Entering Instrument Station Data and Azimuth
Angle PROCEDURE Reading in Registered
Coordinate Data"
4. Select "PT2" and press {ENT} to proceed to 2nd target
input.
5. Input coordinates for the 2nd target and press [OK].
The following values are displayed:
SD: Slope distance of the starting position and 2nd target.
HD: Horizontal distance of the starting position and 2nd
position.
VD: Height difference of the starting position and 2nd target.
• Target height of the starting position and 2nd target can be
input.
Press [Tgt.h] on the second page.
Input the target heights and press [OK].
• Press [COORD] to re-input coordinates for the first or 2nd
targets.
• Pressing [REC] displays the result recording screen for
missing line measurement. Pressing [OK] records the
measured results.
21. MISSING LINE MEASUREMENT
MLM
Occ.Orien.
MLM
MLM
SD
ZA
HA-R
COORD
N
E
Z
LOAD
Input Coord
PT1
PT2
MLM
SD
HD
VD
MOVE
Target height
P T 1
P T 2
96
Set PT1
8 0
4 2
1 5
P2
1 4 0
4 2
1 5
T
t.h
S/%
g
PT1
20.000
30.000
40.000
OK
REC
20.757m
27.345m
1.012m
REC
MEAS
MLM
1. 500
m
1. 500m
OK