Connection via RS232C Cable

RS232C communication is possible, connecting instrument and a data collector with the cable.
PROCEDURE Basic cable settings
1. Power OFF the instrument and connect the instrument and
a data collector with a interface cable.
Cables: "39. ACCESSORIES"
• Insert the interface cable to the serial/external power
source connector tightly and then turn it.
2. Select "Comms setup" in Config mode.
3. Select "Comms mode" in <Communication Setup>.
4. Set "Comms mode" to "RS232C".
5. Select "RS232C" in <Communication Setup>.
6. Perform communication setting for RS232C.
Items set and options (*: Factory setting)
(1) Baud rate
: 1200/2400/4800/9600*/19200/
38400bps
(2) Data bits
: 7/8* bits
(3) Parity
: Not set*/Odd/Even
(4) Stop bit
: 1*/2 bits
7. Press {ENT} to finish settings.
9. CONNECTING TO EXTERNAL DEVICES
Config
Obs.condition
Instr.config
Key function
Comms setup
Instr.const
Comms setup
Comms mode
Comms type
RS232C
Bluetooth
Comms mode
:
RS232C
Comms setup
Comms mode
Comms type
RS232C
Bluetooth
Baud rate
Data bits
Parity
Stop bit
32
: 9600bps
: 8bit
: None
: 1bit