ZOOm:<wfm>:VERTical:POSition
Description
This command sets or queries the Zoom vertical position of the specified waveform.
Group
Zoom
Syntax 1
ZOOm:<wfm>:VERTical:POSition <NR3>
Syntax 2
ZOOm:<wfm>:VERTical:POSition?
Argument
• <NR3>
This is the vertical position, expressed in divisions.
Example 1
ZOOm:CH1:VERTical:POSition?
This query might return
, indicating that the zoomed trace is
:ZOOm:CH1:VERTical:POSition 0.0000
centered at division 0 of the acquire trace.
Example 2
ZOOm:CH1:VERTical:POSition 2
This command sets the vertical position to 2, which centers the zoom trace at the second division of the
acquire trace.