Replacement Modules - GE G30 Instruction Manual

Ur series generator protection system
Hide thumbs Also See for G30:
Table of Contents

Advertisement

2 PRODUCT DESCRIPTION
Table 2–7: G30 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS)
G30
-
*
**
- *
*
* - F
Replacement modules can be ordered separately. When ordering a replacement CPU module or faceplate, provide the
serial number of your existing unit.
Not all replacement modules may be applicable to the G30 relay. Only the modules specified in the order codes are
available as replacement modules.
NOTE
Replacement module codes are subject to change without notice. See the ordering page at
http://www.gegridsolutions.com/multilin/order.htm
NOTE
The replacement module order codes for the horizontal mount units are shown below.
Table 2–8: ORDER CODES FOR REPLACEMENT MODULES, HORIZONTAL UNITS
POWER SUPPLY
redundant supply only available in horizontal units
and must be same type as main supply, for example
must swap both power supplies when switching from
RH to SH
CPU
FACEPLATE/DISPLAY
CONTACT INPUTS AND OUTPUTS
CT/VT MODULES
(NOT AVAILABLE FOR THE C30)
INTER-RELAY COMMUNICATIONS
GE Multilin
**
- H
**
- M
**
-
P/R
**
Reduced Size Vertical Mount (see note regarding P/R slot below)
7Q
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode Laser
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W
RS422, 2 Channels
for the latest options.
UR
-
**
-
*
|
SH
A
|
125 / 300 V AC/DC
|
SL
H
|
24 to 48 V (DC only)
|
T
|
RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
|
U
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
|
V
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
|
3C
|
Horizontal faceplate with keypad and English display
|
3D
|
Horizontal faceplate with keypad and French display
|
3R
|
Horizontal faceplate with keypad and Russian display
|
3A
|
Horizontal faceplate with keypad and Chinese display
|
3P
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and English display
|
3G
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and French display
|
3S
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and Russian display
|
3B
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and Chinese display
|
3K
|
Enhanced front panel with English display
|
3M
|
Enhanced front panel with French display
|
3Q
|
Enhanced front panel with Russian display
|
3U
|
Enhanced front panel with Chinese display
|
3L
|
Enhanced front panel with English display and user-programmable pushbuttons
|
3N
|
Enhanced front panel with French display and user-programmable pushbuttons
|
3T
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
3V
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
3I
|
Enhanced front panel with German display
|
3J
|
Enhanced front panel with German display and user-programmable pushbuttons
|
4A
|
4 Solid-State (no monitoring) MOSFET outputs
|
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
|
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
|
4D
|
16 contact inputs with Auto-Burnishing
|
4L
|
14 Form-A (no monitoring) Latching outputs
|
67
|
8 Form-A (no monitoring) outputs
|
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 contact inputs
|
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 contact inputs
|
6C
|
8 Form-C outputs
|
6D
|
16 contact inputs
|
6E
|
4 Form-C outputs, 8 contact inputs
|
6F
|
8 Fast Form-C outputs
|
6G
|
4 Form-A (voltage with optional current) outputs, 8 contact inputs
|
6H
|
6 Form-A (voltage with optional current) outputs, 4 contact inputs
|
6K
|
4 Form-C and 4 Fast Form-C outputs
|
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 contact inputs
|
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 contact inputs
|
6N
|
4 Form-A (current with optional voltage) outputs, 8 contact inputs
|
6P
|
6 Form-A (current with optional voltage) outputs, 4 contact inputs
|
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 contact inputs
|
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 contact inputs
|
6T
|
4 Form-A (no monitoring) outputs, 8 contact inputs
|
6U
|
6 Form-A (no monitoring) outputs, 4 contact inputs
|
6V
|
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 contact inputs
|
8L
|
Standard 4CT/4VT with enhanced diagnostics
|
8N
|
Standard 8CT with enhanced diagnostics
|
8M
|
Sensitive Ground 4CT/4VT with enhanced diagnostics
|
8R
|
Sensitive Ground 8CT with enhanced diagnostics
|
2A
|
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
|
2B
|
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
|
2E
|
Bi-phase, single channel
|
2F
|
Bi-phase, dual channel
|
2G
|
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
|
2H
|
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
|
2I
|
Channel 1 - IEEE C37.94, multimode, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
|
2J
|
Channel 1 - IEEE C37.94, multimode, 64/128 kbps; Channel 2 - 1550 nm, single-mode, Laser
G30 Generator Protection System
2.2 ORDER CODES

2.2.4 REPLACEMENT MODULES

2
2-15

Advertisement

Table of Contents
loading

Table of Contents