2.1 INTRODUCTION
Roles
|------------ Protection Summary
Commands
|------------ Virtual Inputs
|------------ Clear Records
|------------ Set date and time
2
User Displays
Targets
Actual Values
|------------ Front Panel Labels Designer
|------------ Status
|------------ Metereing
|------------ Transducer I/O
|------------ Records
|------------ Product Info
Maintenance
|------------ Modbus Analyzer
|------------ Change Front Panel
|------------ Update Firmware
|------------ Retrieve File
Table Notes:
1.
RW = read and write access
2.
R = read access
3.
Supervisor = RW (default), Administrator = R (default), Administrator = RW (only if Supervisor role is disabled)
4.
NA = the permission is not enforced by CyberSentry Security
CYBERSENTRY USER AUTHENTICATION
There are two types of authentication supported by CyberSentry that can be used to access the UR device:
Device Authentication (local UR device authenticates)
Server Authentication (RADIUS server authenticates)
The EnerVista software allows access to functionality that is determined by the user role, which comes either from the local
UR device or RADIUS server.
The EnerVista software has a device authentication option on the login screen for accessing the UR device. When the
"Device" button is selected, the UR uses its local authentication database and not the RADIUS server to authenticate the
user. In this case, it uses its built-in roles (Administrator, Engineer, Supervisor, Observer, Operator, or Administrator and
Supervisor when Device Authentication is disabled) as login names and the associated passwords are stored on the UR
device. As such, when using the local accounts, access is not user-attributable.
In cases where user attributable access is required especially to facilitate auditable processes for compliance reasons, use
RADIUS authentication only.
When the "Server" Authentication Type option is selected, the UR uses the RADIUS server and not its local authentication
database to authenticate the user.
No password or security information are displayed in plain text by the EnerVista software or UR device, nor are they ever
transmitted without cryptographic protection.
CyberSentry Server Authentication
The UR has been designed to automatically direct authentication requests based on user names. In this respect, local
account names on the UR are considered as reserved, and not used on a RADIUS server.
2-8
Administrator
Engineer
NA
NA
RW
RW
RW
RW
RW
RW
RW
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
RW
RW
NA
NA
RW
RW
Yes
No
Yes
No
G30 Generator Protection System
2 PRODUCT DESCRIPTION
Operator
Supervisor
Observer
NA
NA
RW
R
RW
R
RW
R
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
NA
NA
RW
R
No
No
No
No
NA
R
R
R
R
R
R
R
R
R
R
R
R
R
R
NA
R
No
No
GE Multilin