2 PRODUCT DESCRIPTION
The order codes for the reduced size vertical mount units with the process bus module are shown below.
Table 2–6: M60 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS)
M60
-
*
**
- *
*
* - F
BASE UNIT
M60
|
|
|
|
|
CPU
E
|
|
|
|
J
|
|
|
|
K
|
|
|
|
N
|
|
|
|
SOFTWARE
00
|
|
|
01
|
|
|
03
|
|
|
04
|
|
|
28
|
|
|
29
|
|
|
30
|
|
|
31
|
|
|
MOUNT/COATING
V
|
|
B
|
|
FACEPLATE/ DISPLAY
F
|
D
|
R
|
A
|
K
|
M
|
Q
|
U
|
L
|
N
|
T
|
V
|
POWER SUPPLY
H
L
PROCESS BUS MODULE
DIGITAL INPUTS/OUTPUTS
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
For the last module, slot P is used for digital
input/output modules; slot R is used for inter-relay
communications modules.
Replacement modules can be ordered separately as shown below. When ordering a replacement CPU module or face-
plate, please provide the serial number of your existing unit.
Not all replacement modules may be applicable to the M60 relay. Only the modules specified in the order codes are
available as replacement modules.
NOTE
Replacement module codes are subject to change without notice. See the web page for the product for the latest
ordering options.
GE Multilin
**
- H
**
- M
**
-
P/R
**
Reduced Size Vertical Mount (see note regarding P/R slot below)
|
|
|
|
Base Unit
|
|
|
|
RS485 and RS485
|
|
|
|
RS485, multi-mode ST 100Base-FX, and 10/100Base-T
|
|
|
|
RS485, multi-mode ST redundant 100Base-FX, and 10/100Base-T
|
|
|
|
RS485 and 10/100Base-T
|
|
|
|
No Software Options
|
|
|
|
Ethernet Global Data (EGD); not available for Type E CPUs
|
|
|
|
IEC 61850; not available for Type E CPUs
|
|
|
|
Ethernet Global Data (EGD) and IEC 61850; not available for Type E CPUs
|
|
|
|
Broken rotor bar detection
|
|
|
|
Broken rotor bar detection and Ethernet Global Data (EGD); not available for Type E CPUs
|
|
|
|
Broken rotor bar detection and IEC 61850; not available for Type E CPUs
|
|
|
|
Broken rotor bar detection, Ethernet Global Data (EGD), and IEC 61850; not available for Type E CPUs
|
|
|
|
Vertical (3/4 rack)
|
|
|
|
Vertical (3/4 rack) with harsh environmental coating
|
|
|
|
English display
|
|
|
|
French display
|
|
|
|
Russian display
|
|
|
|
Chinese display
|
|
|
|
Enhanced front panel with English display
|
|
|
|
Enhanced front panel with French display
|
|
|
|
Enhanced front panel with Russian display
|
|
|
|
Enhanced front panel with Chinese display
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
|
|
|
125 / 250 V AC/DC power supply
|
|
|
|
24 to 48 V (DC only) power supply
|
81
|
|
Eight-port digital process bus module
XX
XX
XX
No Module
4A
4 Solid-State (no monitoring) MOSFET outputs
4B
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4 Solid-State (current with optional voltage) MOSFET outputs
4D
16 digital inputs with Auto-Burnishing
4L
14 Form-A (no monitoring) Latching outputs
67
8 Form-A (no monitoring) outputs
6A
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
8 Form-C outputs
6D
16 digital inputs
6E
4 Form-C outputs, 8 digital inputs
6F
8 Fast Form-C outputs
6G
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
4 Form-C and 4 Fast Form-C outputs
6L
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching output, 8 digital inputs
2A
C37.94SM, 1300nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
72
1550 nm, single-mode, LASER, 1 Channel
73
1550 nm, single-mode, LASER, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, LASER
75
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode LASER
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multi-mode, LED, 1 Channel
7B
1300 nm, multi-mode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, LASER, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multi-mode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multi-mode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multi-mode, LED, 2 Channels
7I
1300 nm, multi-mode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, LASER, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multi-mode, LED
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multi-mode, LED
7N
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
7Q
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode LASER
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W
RS422, 2 Channels
M60 Motor Protection System
2.1 INTRODUCTION

2.1.3 REPLACEMENT MODULES

2
2-7

Advertisement