Cleaning Robot Mount T1 With A7 Mig Gun 500-W - Kemppi Robot Gun Mount T1 Operating Manual

Table of Contents

Advertisement

14.2 Cleaning robot mount T1 with A7
MIG Gun 500-w
This section describes how to clean robot mount T1 with
A7 MIG Gun 500-w.
Figure 13: Cleaning robot mount T1 with A7 MIG Gun 500-w
1.
O-ring, 36×2
2.
Gas duct
3.
Set screw
4.
Robot mount T1
5.
4 O-rings, 3×1.5
6.
2 O-rings, 7×1.5
7.
2 compression sleeves
8.
2 compression springs
Risk of injury
Serious injuries can be caused by parts articulating rapidly.
When cleaning with compressed air, wear suitable
protective clothing – in particular, safety goggles.
9.
2 balls
10. Screw
11. Washer
12. Fastening screw
13. Retaining ring
14. Bellows
© Kemppi Oy 2016
Proceed as follows:
1.
Pull off the retaining ring (13), together with the bellows (14).
2.
Check the O-ring (1) for wear, and replace it if necessary. Before replacing, grease
the O-rings (1) with sealing grease (included in the delivery).
3.
Remove the screw (10), washer (11), and fastening screw (12), and clean them, as a
single assembly, with compressed air.
4.
Blow compressed air through the bores.
5.
Remove the balls (9), compression springs (8), and compression sleeves (7); check
them for damage; and replace them if necessary.
6.
Clean robot mount T1 (4) with compressed air.
7.
Grease the O-rings (6 and 5) with sealing grease (included in the delivery).
8.
Mount the O-rings (6 and 5) on the compression sleeves (7).
9.
Mount the balls (9), compression springs (8), and compression sleeves (7).
10. Detach the set screw (3) and gas duct (2), and check them. If necessary, replace
them.
11. Reinstall the fastening screw (12), washer (11), and screw (10).
12. Attach the bellows (14) and retaining ring (13).