2.2. SITING THE MACHINE

Site the machine on a stationary, horizontal, dry and clean base from which there doesn´t come
any dust etc. into inlet air through the rear grate. Ensure the free circulation of the cooling air.
Degree of protection IP23C of the machine allows at its maximum the water jet coming in 60°
angle to hit machine´s outer covering. See to that the machine is positioned away from the line
of the particle spray, created by grinding tools etc.
-
There must be free space in front of the machine as well as at the rear of the
machine to allow good circulation of the cooling air through the machine.
-
Protect the machine against straight rain and in circumstances over 25 °C against
direct sunshine.
max. 15 °

2.3. CONNECTION TO THE MAINS SUPPLY

Connection and change of the mains cable and the plug must be carried out only by a competent
electrician.
Remove for the mounting of the mains cable the left side plate, seen from the front of the
power source.
The Kempomat power source is equipped with 5 m supply cable without plug. The mains cable
is according to the marking H07RN-F of the norm CENELEC HD22. The mains cable must be
changed if it doesn´t meet local regulations.

2.4. MOUNTING OF THE MAINS CABLE

In cables of S type there is protective grounding conductor coloured green-yellow.
The cable is entered into the machine through the inlet ring on the rear wall of the machine
and locked with a cable clamp (05).
The phase conductors of the cable are coupled to connectors L1, L2 and L3. The earth protection
coloured green-yellow is coupled to connector marked with earth protection symbol
you are using 5-conductor cable, you must cut the zero conductor to the level of the cable´s
protective shield.
Sizes of mains cables and fuse ratings for the machine at 100% ED duty cycle are specified
in the table below:
L1
L2
L3
4 / Kempomat 2500, Kempomat 3200, Kempomat 4000 / 0340
60 °
rain water