12. OPERATION

The device may only be operated by qualified personnel.
Because the robot mount is integrated into the gun's welding process, the operation
steps are performed after the relevant gun has been installed.
Please observe the operating instructions for the A7 MIG Gun 500-g or the A7 MIG Gun
500-w welding guns, as appropriate.

13. UNMOUNTING

Unmounting may only be carried out by specialist personnel. Please make sure that
the shutdown procedures for all components mounted in the welding system are strictly
observed before removal from operation begins.
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, unmounting, and repair work, the
following instructions must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Pull the power plug.
Removal from operation depends on the type of welding gun. Please observe the
operating instructions for the 7 MIG Gun 500-g or the A7 MIG Gun 500-w welding
guns, as appropriate.
16
© Kemppi Oy 2016

14. MAINTENANCE AND CLEANING

Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-
free operation.
Once a month, thoroughly clean the robot mount to remove all dirt and welding spatter.
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, unmounting, and repair work, the
following instructions must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Pull the power plug.
Electric shock
Dangerous voltage can be produced because of defective cables.
• Check all live cables and connections for proper installation.
• Replace any parts that have suffered damage, deformation, or wear.
The maintenance intervals listed are recommended values and assume single-shift
operation.
• Maintenance and cleaning work may only be carried out by qualified and
trained specialists.
• Always wear your personal protective clothing when performing maintenance
and cleaning work.
• When replacing the liquid-cooled A7 MIG Gun 500-w hose assemblies, make
sure that any coolant residues are removed from the robot mount.
• The maintenance intervals listed are recommended values and assume single-
shift operation.