Application And Setting Notes - Siemens 7SJ82 Manual

Siprotec 5 overcurrent protection
Table of Contents

Advertisement

Control Functions
8.2 Switching Devices
Properties
Treatment of spontaneous
position changes (Gen. Soft-
ware Filt./Spont. Software Filt.)
Spontaneous software
filtering time
Spontaneous retrigger
filter (yes/no)
Spontaneous indication
timestamp before filtering
(yes/no)
Inhibit intermediate posi-
tion for a spontaneous
chng. (yes/no)
Table 8-3
Properties
Chatter blocking (yes/no)
Table 8-4
Properties
Number of permissible
status changes
Chatter test time
Number of chatter tests
Chatter idle time
Chatter check time
The inputs and outputs as well as the setting options of the Circuit-breaker and Control function blocks are
described in the next section (see
Interlocking
The Interlocking function block generates the releases for switchgear interlocking protection. The actual
interlocking conditions are deposited in CFC. For more information on this, see the overreaching chapter
8.3.1 Command Checks and Switchgear Interlocking

Application and Setting Notes

8.2.2.2
Circuit Breaker
The Circuit-breaker function block in the SIPROTEC 5 device represents the physical switch device. The task of
the circuit breaker is to replicate the switch position from the status of the binary inputs.
1080
Function
If you select the General soft-
ware filter setting, the general
settings for software filtering of
spontaneous position changes and
for position changes caused by a
switching command apply. By
selecting Spontaneous soft-
ware filter, a separate filtering
is activated for spontaneous posi-
tion changes.
Software filtering time for sponta-
neous position changes
Switching on/off retriggering of the
filtering time by spontaneous posi-
tion change
Consideration of the hardware
filtering time for position-detection
time stamp in case of a sponta-
neous change
When activated, only the sponta-
neous change to the intermediate
position is suppressed by the dura-
tion of the software filtering time.
Setting Options of the Controllable Position in the Circuit-Breaker Function Block (Chatter
Blocking)
Function
Switching chatter blocking on/off
Additional Settings in the Device Settings having Effects on the Circuit Breaker
Function
Chatter-blocking setting value:
Once for the entire device
8.2.2.3 Connection Variants of the Circuit
To Be Found in
Position of the Control function
block
34
Position of the Control function
block
34
Position of the Control function
block
34
Position of the Control function
block
34
Position of the Control function
block
34
To Be Found in
Position of the Circuit-breaker
function block
To Be Found in
Device settings (to be found under
Settings)
Breaker).
Protection.
SIPROTEC 5, Overcurrent Protection, Manual
C53000-G5040-C017-8, Edition 07.2017
34

Advertisement

Table of Contents
loading

This manual is also suitable for:

7sj85

Table of Contents