VERSION 07/2014
OPERATING MANUAL
8.2.4
HYDRAULIC STAGE MAINTENANCE
Dismount the pump as shown in the picture and place it upside down on a suitable underlay. Align horizontally.
Observe the fi ll level marking (X) on the oil tank.
8.2.5
CHECKING THE OIL LEVEL
1 Start up the pump for a short time without any product.
2 Then read oil level A.
Dismount the pump as shown in the picture and place it upside
down on a suitable underlay. Align horizontally.
Observe the fi ll level marking (X) on the oil tank.
Oil level A in the oil tank (3) has to be within the specifi ed
markings (X).
If the level deviates from these markings, the hydraulic oil must be
topped up or removed by suction.
Procedure:
1 Unscrew and remove threaded plug (5).
2 Top up oil to level A = middle of marking X.
3 Start up the pump for a short time without any product and check for air bubbles.
4 Screw in threaded plug (5) and tighten with 2 Nm; 1.5 lbft.
Using hydraulic oil
Using the wrong hydraulic oil can cause a malfunction.
Use only original hydraulic oil - Wagner Order No. 322912 (250 ml or 15 cu inch).
ORDER NUMBER DOC2349980
B_05067
NOTICE
B_05068
5
Max.
Min.
3
A
B_05069
44