Fault History - ABB ACS150 User Manual

0.37...4 kw, 0.5...5 hp
Table of Contents

Advertisement

Actual signals
No.
Name/Value

04 FAULT HISTORY

0401
LAST FAULT
0402
FAULT TIME 1
0403
FAULT TIME 2
0404
SPEED AT FLT
0405
FREQ AT FLT
0406
VOLTAGE AT FLT
0407
CURRENT AT FLT
0408
TORQUE AT FLT
0409
STATUS AT FLT
0412
PREVIOUS FAULT 1
0413
PREVIOUS FAULT 2
0414
DI 1-5 AT FLT
Description
Fault history (read-only)
Fault code of the latest fault. See chapter
clear (on panel display = NO RECORD).
Day on which the latest fault occurred.
Format: The number of days elapsed after power-on.
Time at which the latest fault occurred.
Format: Time elapsed after power-on in 2 second ticks (minus the whole days stated by
signal
0402
FAULT TIME 1). 30 ticks = 60 seconds.
E.g. Value 514 equals 17 minutes and 8 seconds (= 514/30).
Motor speed in rpm at the time the latest fault occurred
Frequency in Hz at the time the latest fault occurred
Intemediate circuit voltage in VDC at the time the latest fault occurred
Motor current in A at the time the latest fault occurred
Motor torque in percent of the motor nominal torque at the time the latest fault occurred
Drive status in hexadecimal format at the time the latest fault occurred
Fault code of the 2nd latest fault. See chapter
Fault code of the 3rd latest fault. See chapter
Status of digital inputs DI1...5 at the time the latest fault occurred. Example: 10000 = DI1
is on, DI2...DI5 are off.
Fault tracing
for the codes. 0 = fault history is
Fault tracing
for the codes.
Fault tracing
for the codes.
Actual signals and parameters
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs350