Parameters in the Long Parameter mode
Index Name/Selection
0, x...x
3202
SUPERV 1 LIM LO
x...x
3203
SUPERV 1 LIM HI
x...x
3204
SUPERV 2 PARAM
x...x
3205
SUPERV 2 LIM LO
x...x
3206
SUPERV 2 LIM HI
x...x
3207
SUPERV 3 PARAM
x...x
3208
SUPERV 3 LIM LO
x...x
3209
SUPERV 3 LIM HI
x...x

33 INFORMATION

3301
FIRMWARE
0.0000...FFFF (hex)
3302
LP VERSION
0x2001...0x20FF
(hex)
3303
TEST DATE
Actual signals and parameters
Description
Parameter index in group
0 = not selected.
Defines the low limit for the first supervised signal selected by parameter
3201
SUPERV 1 PARAM. Supervision wakes up if the value is below the
limit.
Setting range depends on parameter
Defines the high limit for the first supervised signal selected by parameter
3201
SUPERV 1 PARAM. Supervision wakes up if the value is above the
limit.
Setting range depends on parameter
Selects the second supervised signal. Supervision limits are defined by
parameters
3205
SUPERV 2 LIM LO and
parameter
3201
SUPERV 1 PARAM.
Parameter index in group
Defines the low limit for the second supervised signal selected by parameter
3204
SUPERV 2 PARAM. Supervision wakes up if the value is below the
limit.
Setting range depends on parameter
Defines the high limit for the second supervised signal selected by parameter
3204
SUPERV 2 PARAM. Supervision wakes up if the value is above the
limit.
Setting range depends on parameter
Selects the third supervised signal. Supervision limits are defined by
parameters
3208
SUPERV 3 LIM LO and
parameter
3201
SUPERV 1 PARAM.
Parameter index in group
Defines the low limit for the third supervised signal selected by parameter
3207
SUPERV 3 PARAM. Supervision wakes up if the value is below the
limit.
Setting range depends on parameter
Defines the high limit for the third supervised signal selected by parameter
3207
SUPERV 3 PARAM. Supervision wakes up if the value is above the
limit.
Setting range depends on parameter
Firmware package version, test date etc.
Displays the version of the firmware package.
E.g. 1.30b
Displays the version of the loading package.
0x2021 = ACS150-0x (Eur GML)
Displays the test date.
Date value in format YY.WW (year, week)
01 OPERATING
DATA. E.g. 102 =
3201
setting.
3201
setting.
3206
SUPERV 2 LIM HI. See
01 OPERATING
DATA. E.g. 102 =
3204
setting.
3204
setting.
3209
SUPERV 3 LIM HI. See
01 OPERATING
DATA. E.g. 102 =
3207
setting.
3207
setting.
Def
0101
SPEED.
-
-
-
-
104
0101
SPEED.
-
-
-
-
105
0101
SPEED.
-
-
-
-
Type
dependent
00.00