Installation

Electrical Connections

Follow these precautions when grounding, connecting
cables, connecting to a power source or making other
electrical connections.
To reduce the risk of fire, explosion, or electric shock:
The control center must be electrically connected to
a true earth ground; the ground in the electrical sys-
tem may not be sufficient.
All wires used for grounding must be 18 AWG mini-
mum.
A qualified electrician must complete all grounding
and wiring connections.
For 24 Vdc wiring refer to F
For 100-240 Vac wiring refer to F
Refer to your local code for the requirements for a
"true earth ground" in your area.
NOTICE
If power and grounding connections are not done
properly, the equipment will be damaged and the
warranty voided.
+
F
. 10: 24 Vdc Wiring
IG
18
. 10.
IG
. 11.
IG
Ground
-
F
. 11: 100-240 Vac Wiring
IG
Connect Light Tower Accessory
1. Order the 255468 Light Tower Accessory as a diag-
nostic indicator for the PCF system.
2. Connect the cable from the light tower to the digital
I/O port (BS) on the ADM.
See Table 3 for a description of light tower signals.
Table 3: Light Tower Signals
Signal
Description
Green
No errors.
Yellow
An advisory exists.
Red flashing
A deviation exists.
Red solid
An alarm exists and the system is
shut down.
NOTE: See Errors, page 55, for error definitions.