Graco PCF Instructions - Parts Manual page 97

Precision dispense system
Hide thumbs Also See for PCF:
Table of Contents

Advertisement

Error Report Screens
There are nine error report screens that display a
chronological list of system errors. These screens dis-
play the last 140 errors. Each error report screen dis-
plays the date, time, error code, and description for each
error. See Errors, page 55, for more information on
errors, a list of error codes, and information on error
troubleshooting.
Press
to scroll through each error report
screen.
Job Report Screens
There are 21 job report screens that store and display a
chronological list of jobs performed by the system. Each
job record includes the date and time the job was com-
pleted; the style dispensed; the error percentage; and
the target, requested, and actual dispense volumes.
Press
to scroll through each job report
screen.
313377L
Appendix A - Advanced Display Module (ADM)
Maintenance Screen
This screen enables users to view the maintenance
totalizers for each system component and the limits set
that will trigger a maintenance advisory.
Maintenance totalizers keep track of the total volume (or
hours) that each system component has been running.
If the totalizer value exceeds the set limit, the totalizer
value will turn red and a maintenance advisory is issued.
The limits are set in the Maintenance Advisory Limits
Screen, page 93, for the air supply, V/P regulator, fluid
regulator, flow meter, and all four guns.
NOTE: If a flow meter is not included in the system,
this screen shows hours instead of volume and the
flow meter entry is grayed out.