Graco PCF Instructions - Parts Manual page 106

Precision dispense system
Hide thumbs Also See for PCF:
Table of Contents

Advertisement

Appendix C - Communications Gateway Module (CGM) Connection Details
EtherNet/IP
NS
F
. 59: EtherNet/IP Fieldbus Connections
IG
The Ethernet interface operates at 100Mbit, full duplex,
as required by PROFINET. The Ethernet interface is
auto polarity sensing and auto-crossover capable.
Network Status (NS)
State
Off
No power or no IP address
Green
On-line, one or more connections established
(CIP Class 1 or 3)
Flashing
On-line, no connections established
Green
Red
Duplicate IP address, FATAL error
Flashing
One or more connections timed out (CIP Class
Red
1 or 3)
Module Status (MS)
State
Off
No power
Green
Controlled by a Scanner in Run state
Flashing
Not configured, or Scanner in Idle state
Green
Red
Major fault (EXCEPTION-state, FATAL error
etc.)
Flashing
Recoverable fault(s)
Red
LINK/Activity (Link)
State
Off
No link, no activity
Green
Link established
Flashing
Activity
Green
106
MS
Link
TI11814A
Description
Description
Description
DeviceNet
NS
1
2
F
. 60: DeviceNet Fieldbus Connections
IG
Network Status (NS)
State
Off
Not online / No power
Green
On-line, one or more connections are
established
Flashing
On-line, no connections established
Green
(1 Hz)
Red
Critical link failure
Flashing
One or more connections timed-out
Red (1 Hz)
Alternating
Self test
Red/Green
Module Status (MS)
State
Off
No power or not initialized
Green
Initialized
Flashing
Missing or incomplete configuration, device
Green (1 Hz)
needs commissioning
Red
Unrecoverable Fault(s)
Flashing
Recoverable Fault(s)
Red (1 Hz)
Alternating
Self test
Red/Green
DeviceNet Connector (DC)
Pin
Signal
1
V-
Negative bus supply voltage
2
CAN_L
CAN low bus line
3
SHIELD
Cable shield
4
CAN_H
CAN high bus line
5
V+
Positive bus supply voltage
MS
3 4 5
TI11815A
DC
Description
Description
Description
313377L

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents