Errors
Error
Gateway
Code
Error No.
Error Name
EAU0
3
Download to
USB in Process
EBU0
4
Download to
USB Complete
WSU0
5
USB configura-
tion error
WNC0
10
ADM Key Token
Error
WMC0 19
Display Error
Detected
CAC0
20
CGM Communi-
cation Error
WMG0 21
Gateway Map
Error
CBG0
22
Gateway Reset
WMG0 29
Gateway Error
Detected
B7C0
30
Style Out of
Range
B40X
31
High Volume or
B30X
High Mass
56
Error
Description
Control Center Errors
Information is currently
Advisory
being downloaded to
(self-clearing)
USB
Download to the USB is
Advisory
complete
(self-clearing)
USB configuration error Advisory
Missing or invalid key
Alarm
token
ADM error detected;
Alarm
includes any error not
covered by another
more specific error
Communication lost
Advisory
between CGM and
ADM
Missing or invalid map
Advisory
Gateway reset
Advisory
(self-clearing)
Gateway error
Alarm
detected; includes any
error not covered by
another more specific
error
Style is out of range
Alarm
Material dispensed
Alarm or
during last dispense
Deviation
cycle was above
(user select-
amount requested plus
able)
the allowed tolerance
Error Type
Cause
n/a
n/a
USB configuration
invalid or not present
An ADM key token is
required to run the
system
ADM and CGM are no
longer communicating
CGM is not functioning Replace the CGM if the
Missing or invalid
Gateway map
Gateway setting(s)
changed
Style requested by
automation controller
exceeds number of
styles in system
PCF regulator is not
regulating correctly
Incorrect style target
volume or tolerance
Solution
No action necessary
No action necessary
Reinstall system soft-
ware on display
Verify the key token is
installed
Verify the key token
part number is correct
for the PCF ADM
Reconnect or replace
CAN cable
red status LED is solid
Install PCF map in
Gateway
Wait for reset to com-
plete before attempt-
ing automation control
Use a style number
that is in range
Increase number of
styles in PCF; pur-
chase accessory key
token
Check regulator and
repair if necessary
Enter correct values or
set tolerance to 0% to
disable fault