Graco PCF Instructions - Parts Manual page 58

Precision dispense system
Hide thumbs Also See for PCF:
Table of Contents

Advertisement

Errors
Error
Gateway
Code
Error No.
Error Name
F6D1
54
Flow Meter Error Flow Meter error
WED1
55
V/P Error
WJD1
56
Dispense Valve 1
Error
WJD2
57
Dispense Valve 2
Error
WJD3
58
Dispense Valve 3
Error
WJD4
59
Dispense Valve 4
Error
WSD1
60
Incompatible
Gun Settings
F7D1
61
Closed Gun Flow System reading flow
V2D1
62
Low Analog
58
Error
Description
Fluid Plate Errors (continued)
Alarm
V/P error
Alarm
Dispense valve 1 error
Alarm
Dispense valve 2 error
Alarm
Dispense valve 3 error
Alarm
Dispense valve 4 error
Alarm
Incompatible settings
Alarm
for multiple gun opera-
tion; attempted to dis-
pense
Alarm
meter pulses with
gun(s) closed
Analog command
Deviation
dropped below mini-
mum value (user
defined) while dispens-
ing
Error Type
Cause
Problem detected with
flow meter
Problem detected with
V/P
Problem detected with
dispense valve 1
Problem detected with
dispense valve 2
Problem detected with
dispense valve 3
Problem detected with
dispense valve 4
Attempted to dis-
pense from multiple
guns with incompatible
settings
Dispense hose leak
Flow meter providing
false pulses
Dispense valve not
operating correctly
Bad or loose com-
mand cable connec-
tion
Entered command
mode incorrectly
Automation program
error
Solution
Verify flow meter is
installed and/or con-
nected correctly
Replace if necessary
Verify outlet pressure
transducer is installed
and/or connected cor-
rectly
Replace if necessary
Verify dispense valve 1
is installed and/or con-
nected correctly
Replace if necessary
Verify dispense valve 2
is installed and/or con-
nected correctly
Replace if necessary
Verify dispense valve 3
is installed and/or con-
nected correctly
Replace if necessary
Verify dispense valve 4
is installed and/or con-
nected correctly
Replace if necessary
Check gun mode set-
tings (on fluid plate
setup screen)
Verify automation pro-
gramming
Check hose; replace if
needed
Replace flow meter
sensor or calibrate
meter
Repair dispense valve
Check command cable
and connection
Enter correct com-
mand code
Verify correct automa-
tion program
313377L