10. If two hoses are used, connect Supply Hose 2 (D) to
the Swivel Fitting (H) on the Dispense Valve (B)
using the Supply Hose 2 to Swivel Fitting (G). If only
one hose is used, connect Supply Hose 1 (C) to the
Swivel Fitting (H) on the Dispense Valve (B) using
the Supply Hose 2 to Swivel Fitting (G).
B
F
. 28
IG
11. Tighten all fittings until secure.
12. Connect the Air Line (AR) (not supplied) to the air
fitting (FT) on the dispense valve solenoid. See the
iQ Dispense Valves Instructions-Parts manual.

Electrical Connections

Pressure Transducer
1. If using a Single iQ Ram Supply System, connect
the pressure transducer cable (PC) to Port 6 on the
Electric Driver (AB). See Electric Driver
Communication Connections for Single Rams on
page 18.
2. If using a Tandem iQ Ram Supply System:
a. Connect the pressure transducer cable (PC) to
the tandem block valve pressure transducer
splitter. See Electric Driver Communication
Connections for Tandem Rams on page 19.
b. Connect one male end of the M12 5 pin splitter
on the tandem block to Port 6 on the Elecrtic
Driver (AB). Connect one cable to each Ram.
333586D
Pressure
Transducer
Splitter
D
F
G
Solenoid
3. If using a Single iQ Ram Supply System:
H
4. If using an iQ Tandem Ram Supply System:
PC
. 29
IG
a. Connect the solenoid valve cable (VC) to Port 4
on the Electric Driver (AB). See Electric Driver
Communication Connections for Single
Rams on page 18.
b. Connect the straight end of the included angled
M8 4 pin cable (15N040) to the dispense valve,
and the straight end of the solenoid valve cable
(VC).
a. Connect the solenoid valve cable to the tandem
block pump solenoid valve splitter. See Electric
Driver Communication Connections for
Tandem Rams on page 19.
b. Connect the straight end of the included angled
M8 4 pin cable (15N040) to the dispense valve,
and the straight end of the solenoid valve cable
(VC).
c. Connect one male end of the M8 4 pin splitter
on the tandem block to Port 4 on the Electric
Driver (AB). Connect one cable to each ram.
Setup