Graco PCF Instructions - Parts Manual page 91

Precision dispense system
Hide thumbs Also See for PCF:
Table of Contents

Advertisement

Fluid Plate Setup Screens
There are seven fluid plate setup screens, which enable
users to:
set controls and gun commands;
set on and off delays for guns and the regulator;
set k-factor, pressure, and flow rate variables;
set offsets for inlet and outlet pressures;
set error types;
and set variables for maintenance advisories.
Press
to scroll through the Fluid Plate
Setup screens. Once in the desired screen, press
to access the fields to make changes. Press
edit mode.
NOTE: Users must be out of edit mode to scroll
through the fluid plate setup screens.
Control Settings Screen
This screen enables users to:
Set the dispense trigger source to Gateway, Com-
mand Cable, or Combined. If it is set to Command
Cable, users can enable the guns.
Set the command value source to Gateway, Com-
mand Cable, or Display.
Set the Job End Timer to Timer or Gateway. If this
field is set to Timer, users can set Job End Delay.
Set the Run Mode Bead Adjust to Enable or Dis-
able.
Set Display Control Password to Enable or Disable.
When entering maintenance mode, a password
prompt will appear if Display Control Password is
set to Enable and a password is set in the Advanced
screens.
313377L
Mode Settings Screen
This screen enables users to set gun commands. Use
this screen to select a mode (pressure, bead, shot, or
full open) for each gun. Users can also set the flow rate
or pressure for each gun, and adjust the bead scale.
NOTE: The ability to dispense from multiple guns
simultaneously is only allowed in either of the fol-
lowing scenarios.
Each gun is set to Pressure mode and has
identical command values.
Each gun is set to Full Open mode.
Attempting to dispense from multiple guns simulta-
neously using any other combination will cause an
to exit
Incompatible Guns Settings alarm.
Appendix A - Advanced Display Module (ADM)
91

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents