Graco PCF Instructions - Parts Manual page 59

Precision dispense system
Hide thumbs Also See for PCF:
Table of Contents

Advertisement

Error
Gateway
Code
Error No.
Error Name
WFD1
63
Flow Meter
Required
EJD1
64
Job Cycle Time
Out
WXD1
65
Fluid Plate Error
Detected
P3F1
66
Maximum Inlet
P4F1
Pressure
P3D1
67
Maximum Outlet
P4D1
Pressure
P1F1
68
Minimum Inlet
P2F1
Pressure
P1D1
69
Low Pressure
P2D1
313377L
Error
Description
Fluid Plate Errors (continued)
Operating mode
Alarm or
requires flow meter.
Advisory
Advisory is issued if
(self-clearing)
fluid plate settings
require a flow meter but
meter is not present.
Alarm is issued if dis-
pense is attempted in
mode that requires a
flow meter but meter is
not present.
Job cycle time out
Alarm
Fluid plate error
Alarm
detected; includes any
error not covered by
another more specific
error
Inlet pressure to regula-
Alarm or
tor is above upper limit
Deviation
set for operation
(user select-
able)
Outlet pressure of regu-
Alarm or
lator is above upper
Deviation
limit set for operation
(user select-
able)
Inlet pressure to regula-
Alarm or
tor is below lower limit
Deviation
set for operation
(user select-
able)
Measured outlet pres-
Alarm or
sure less than desired
Deviation
outlet pressure minus
(user select-
tolerance
able)
Error Type
Cause
Selected gun mode
settings require flow
meter
FCM key token miss-
ing or invalid
Automation signals did
not properly end job
cycle
Incorrect set limit
Material supply pres-
sure is too high
Failed transducer
Incorrect set limit
Material supply pres-
sure is too high
Failed transducer
Incorrect set limit
Material supply pres-
sure is too low
Failed transducer
Incorrect limit set
No or insufficient
material flow
Dispense valve needle
is stuck closed
Dispense valve leak-
ing
Regulator not operat-
ing correctly
Pump wink passed
through outlet
Failed transducer
Errors
Solution
Check gun mode set-
tings
Purchase meter
enabled token for FCM
and install flow meter
Check for FCM key
token error
Check automation pro-
gramming per job
operating instruction
Verify limit is set cor-
rectly
Decrease material sup-
ply pressure
Check transducer;
replace if necessary
Verify limit is set cor-
rectly
Decrease material sup-
ply pressure
Check transducer;
replace if necessary
Verify limit is set cor-
rectly
Increase crease mate-
rial supply pressure
Check transducer;
replace if necessary
Verify limit is set cor-
rectly
Increase material flow
rate
Dislodge and inspect
needle
Repair dispense valve
Repair regulator
Increase pump pres-
sure
Check transducer;
replace if failed
59