Upgrade Fluid Control Module
(FCM) Software
NOTE: The FCM connection is temporarily disabled
during the installation of the upgrade a key token.
1. Turn off power to the system.
2. Remove access cover.
F
. 37: Remove Access Cover
IG
3. Insert and press token firmly into slot.
NOTE: There is no preferred orientation of token.
4. Turn on power to the system. The red indicator light
(CK) will flash until new software is completely
loaded.
CK
F
. 38: Insert Token
IG
5. After the red indicator light shuts off, turn off power
to the system.
6. Remove token.
7. Replace access cover.
313377L
Access
Cover
TI12334A
TI12335A
Token

Air Filter Maintenance

To prevent filter element damage, replace air filter every
two years or when pressure drop becomes 0.1 MPa (1.0
bar, 14.5 psi); which ever occurs first.
Replacement Air Filters
Part
Description
123091
5 micron air filter
123092
0.3 micron air filter
Maintenance