Appendix A - Advanced Display Module (ADM)
Delay Settings Screen
This screen enables users to set on and off delays (in
milliseconds) for each gun and the regulator
explanation of the on and off delays, refer to the On/Off
Delays section on page 32.
Flowmeter and Control Loop Settings Screen
This screen enables users to set the meter type (volume
or mass) and the K-Factor for the flowmeter. Users can
also set the Kp, Ki, and Kd for the pressure control loop
as well as Kp and Ki for bead control loop.
NOTE: In systems without a flow meter, the flow
meter settings will be grayed out.
NOTE: It is recommended that these values not be
changed from the factory defaults of 32.00 for Kp,
128.00 for Ki, and 0.00 for Kd.
92
Pressure Sensors Screen
NOTE: Inlet sensor settings will be grayed out on
.
this screen for systems with heated fluid plates.
For an
This screen enables users to:
Set the offset for the inlet and outlet pressures.
NOTE: The offset value must be set to a
non-zero value before '-' can be selected from
the +/- drop-down menu.
Set the minimum and maximum pressure limits for
the inlet, and the maximum pressure limit for the
outlet.
Set the error type (alarm or deviation) that will be
issued if the inlet and/or outlet pressure go outside
of the set limits.
313377L