AUDIO AND VIDEO DOOR ENTRY SYSTEM - ACCESS CONTROL
MODULE PROGRAMMING
Programming mode entry and exit:
To enter programming mode, press the key button three times and then enter secret administrator pin "271800".
To exit programming mode, press the C button (cancel) once if it is in a programming field or twice if not.
If, after 2 minutes, no key has been pressed, it exits programming mode.
Programming mode entry and exit is confirmed by the emitting of 5 rapid beeps.
Important:
* ( )
Bear in mind the number of digits in the configured code (factory setting 2718 = 4).
Programming mode structure and sequence:
Programming of the keypad functions is performed by entering the field or function code, followed by the field
value(s).
Once in programming mode, the programming sequence is as follows:
0
Enter the field code: this code is always 1 digit. The keypad will emit 2 rapid confirmation beeps.
Enter the value of the field being programmed. Once the value has been entered, the keypad will emit 2
4
rapid confirmation beeps. To finish programming the field, press the key button and the keypad will emit 4
rapid confirmation
Note: If, after 10 seconds, no key has been pressed, a long error beep will be emitted and the field code will
need to be re-entered.
1
C
Enter the code of the following field or press the C button (cancel) to exit programming mode.
or
If an incorrect value has been entered, press the C button (cancel). The keypad will emit a long confirmation beep. If
the field code was being entered, even after the confirmation beep, exit this menu and re-enter the field code.
Field
4
2
C
key button + key button + key button + administrator
beeps.
Field value
1
2
2
C
C
2
7
Field value
0
2
C
C
C
pin.
* ( )
1
8
Field value
03
2
C
11
* ( )
Finish