MODULE PROGRAMMING
Programming fields:
Continued from previous page
Field "6": Configuring locking mode.
Allows the access control module's locking mode to be configured.
Steps: Field + locking mode + time between attempts + lock time + panic output + key button.
6
(Step 1)
(Step ) 2
0
(Step ) 3
0
(Step ) 4
0
(Step ) 5
(Step ) 6
7
(Step ) 7
0
6
Press "6" to select field "6".
Set the access control module's locking mode.
0
Enter one of the following options:
"0": Never locks.
"3" to "9": Locks after "3" to "9" failed attempts to enter the user pin.
Set the minimum amount of time that must elapse between failed attempts before the
1
access control module is locked. Only takes effect if option "0" has not been selected in
step 2.
The times to select are "01" to "15" minutes or press the key button.
Note: If the key button is pressed, this field value is set as "03"
( )
*
field value is "03"
programming of the field
Set the amount of time that the access control module remains in locking mode after the
1
last wrong code has been entered. Only takes effect if option "0" has not been selected in
step 2.
The times to select are "03" to "15" minutes or press the key button.
Note: If the key button is pressed, the field value is set as "03"
( )
*
value field is "0"
Set the activation of the panic output (terminal "P" of the terminal block) during locking
1
or
mode. Only takes effect if option "0" has not been selected in step 2.
Enter one of the following options or press the key button:
"0" : Output not activated.
"1" : Output activated (for 3 seconds in intervals of 1 minute).
Note: If the key button is pressed, the field value is set as "0" and the programming of the
( )
*
field finishes.
Press the key button to finish programming the field.
Note: It is not necessary to press the key button if it has already been pressed in steps
3, 4 or 5.
Then press the number of the next field to configure or press the C button (cancel) to exit
C
or
programming mode.
0
1
0
minutes
, the "panic output" value field is "0"
finishes.
not activated
and the programming of the field finishes
3
0
1
or
( )
*
minutes
not activated
( )
*
minutes
( )
*
18
, the "locking time"
and the
, the "panic output"
.
Continued overleaf