IN100 Cylindrical Lock

Operational Check

7
1. Insert key into cylinder and rotate (Fig. 14A).
There should be no friction against lock case, wire
harness or any other obstructions.
2. Check that the key retracts the latch.
The key should rotate freely.
3. Try the inside lever; ensure it retracts latch.
4. Present a valid credential* (Fig. 14B) to unlock
outside lever; turn lever handle to ensure latch retracts.
Fig. 14A
Note: The credential should approach the inscription
on the reader as indicated (Fig. 14B) to ensure
the credential is read properly.
Do not wave credential.
Fig. 14B