Lock Self-Test LED indication

After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using
a series of red and green LED flashes as described by the figures below.

LED indication after power up/replacement of the battery

8.3.1

Battery not fully charged

Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at the
right voltage or a backward battery has been installed; battery not fully charged; energy counter
not reset or no Power on self-test done.
Error in lock,
maintenance required
8.3.2

Test pass

1 red (1s) + 1 green (1s), Power on self-test passed, see table below.
POST Successful
Figure 6. Lock POST LED
indication
8.3.3
Test fail
1 red (1s) + 3 blinks (500ms, green or red), at least one test failed (red), see table below.
If a fatal error is detected the lock will enter an Error state and continuously indicating fatal error
and will not read cards nor unlock.
FATAL ERROR
CABLE ERROR
MECHANICAL ERROR
FATAL ERROR
CABLE ERROR
MECHANICAL ERROR
22
1-800-810-WIRE • www.sargentlock.com • A8189B
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can't close)
One red, one green flash
(1 second)
1 sec
0.5 sec
0.5 sec
Tests core functionality.
MCUs, memory and
internal communication, etc.
Tests communication between the different
parts in the system, i.e. different boards
connected with a wire.
Test related to moving parts of the lock.
IN100 Cylindrical Lock
0.5 sec