LED Indications

8
The communication hub has a single LED. It supports an optical scheme of red,
green and yellow.
The indication scheme is described by the figures below:
Figure 1.
Communication hub normal
operation LED indication
Some special LED indication schemes are
used during lock maintenance actions:
Figure 2.
Communication hub
maintenance LED indication
The LED on the AH40 communication hub indicates both the
status of the Ethernet link level and ethernet communication:
Figure 3.
AH40 Communication hub

Ethernet LED indication

20
1-800-810-WIRE • www.sargentlock.com • A8189B

Communication Hub LED indications

Online
Aperio
lock
®
offline
EAC offline
Aperio
lock and
®
EAC offline
UHF
communication
Pairing active
Ethernet LED indication
Ethernet link
connected
Ethernet
communication
*For more information, refer to Aperio Online Quick Installation Guide
Document No: ST-001322-PF Date: 2015-12-23
IN100 Cylindrical Lock
2 sec.
Green
Green + one
red flash
Green + two red flashes
Green + three
red flashes
Yellow + off,
fast flash
2 sec.
2 sec.
Green
Green +
off fast flash
Yellow + green