10 Outside Reader Installation (Continued)

Installation of Connectors

CAUTION - Do not touch or allow debris to enter connector contacts.
Secure the following connectors to their respective terminals (Fig. 11D):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
*NOTE: Optional 2-pin external 9-24VDC power connector.
IMPORTANT: Do not run wires through bottom hole in plate - it will
damage wires and the controller connector.
Route wires around flange, do not route wires through
the flange hole (Fig. 11B, D).
C. When all connections have been made, tuck excess cable
into wire hole on inside of door.

Secure Mounting Plate

D. Secure the mounting assembly while ensuring proper
alignment of outside reader and tighten the (2) through-bolts
on the inside of the door to secure the reader (Fig. 11E).
E. Secure the 24-pin card reader connector (Fig. 11F).
16
1-800-810-WIRE • www.sargentlock.com • A8189B
IN100 Cylindrical Lock
DPS (4-pin)
Ground
Lug
Fig. 11D
Fig. 11E
Reader
(24-pin)
Board-to-Board
Connector
9-24VDC
Power*
A
B
Lock
Body
(10-pin)
Fully
tighten
D
Fig. 11F