Page 1
Aperio ™ Technology Cylindrical Lock Installation Instructions A8189B 07/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Parts Breakdown ..............5 Lock Installation ..............7 Operational Check ..............19 Lock LED Indications ............20 Changes or modifications to this device not expressly approved by ASSA ABLOY Warning could void the user’s authority to operate the equipment. FCC: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
IN100 Cylindrical Lock Parts Breakdown ITEM PART NUMBER/ORDER STRING DESCRIPTION COLOR/TRIM IN-100-EM0110G77-IP-B HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE Black ® ® ® ® SE, HID DESfire EV1 SE, HID Prox , NFC-enabled mobile phones ®...
Page 6
IN100 Cylindrical Lock Parts Breakdown (Continued) PART NO./ORDER ITEM STRING DESCRIPTION QTY. Outside Lever (Reference Catalog for Available Styles) 10-0043 Lever Retainer Key (In Screw Pack 10-2052) Cylinder Assembly (Reference Catalog for Available Cylinders) Rose (Reference Catalog for Available Styles) 10-0792 Spacer Bushing 10-3049...
IN100 Cylindrical Lock Lock Installation 1 Prepare Door A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. Fig. 1A LHRB RHRB Left Hand Left Hand Right Hand Right Hand Hinges Left Reverse Bevel Hinges Right Reverse Bevel Open Inward...
Page 8
IN100 Cylindrical Lock Centerline of 2 Install Strike Latch Front and Strike Install strike in the door frame (Fig. 2). (2) #8-32 x 3/4" Latch Screws Fig. 2 3 Install Latchbolt 1. Install latch with beveled bolt facing the strike. Inside of Door 2.
Page 9
IN100 Cylindrical Lock 5 Lock Adjustments A. Lock Preset: • Lockbody holes: 12 and 6 o’clock (Fig. 5). The lock is shipped “preset” and does not require adjustment for 1-3/4” thick doors. Outside of Door Door thickness: 1-3/4” thick Preset Lock Fig.
Page 10
IN100 Cylindrical Lock 6 Through-Bolt and Door Thickness Adjustment (If Required) A. Remove Outside Lever 1. Insert key, rotate 45° clockwise and hold. 2. Depress lever retainer with push pin tool (provided). 3. Pull lever outward. Outside of Door B. How To Change Cylinder (If Necessary) Fig.
Page 11
IN100 Cylindrical Lock C. Through-Bolt and Door Thickness Adjustment 1. (If necessary) remove outside lever, scalp and spacer bushing (Fig. 6C). Spacer Bushing Scalp Outside Lever Fig. 6C 2. Rotate mounting plate to either align with through-bolt holes in door, or adjust for proper door thickness (Fig. 6D). Refer to markings on through-bolt post (Fig.
Page 12
IN100 Cylindrical Lock 7 Install Lock 1. From outside of door feed lockbody harness into the lockbody hole (Fig. 7A). For metal door: Feed harness through inside of door (not shown). 2. Continue to feed harness into raceway (towards top of door), exiting raceway hole on inside of door (Fig.
Page 13
IN100 Cylindrical Lock 8 Secure Lock to the Door 1. Slide inside rose assembly and spacer bushing over lockbody. 2. Position ground lug between (top) #10-32x1-1/4” through-bolt and rose assembly (Fig. 8A). NOTE: Proper placement of ground wire (Fig. 8B) will prevent Inside of Door pinching/damage to the ground wire.
Page 14
IN100 Cylindrical Lock 10 Outside Reader Installation 1. Orient the reader so the LED lens is at the top (Fig. 10A). 2. Feed the cable/connector through the door (from outside to inside). 3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes.
Page 15
IN100 Cylindrical Lock 10 Outside Reader Installation (Continued) 4. Feed the reader harness and DPS connectors through the inside mounting assembly (and gasket if required*). See Figure 11B. IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 11B, C) - it will damage wires and the controller connector.
Page 16
IN100 Cylindrical Lock 10 Outside Reader Installation (Continued) Installation of Connectors 9-24VDC DPS (4-pin) Power* CAUTION - Do not touch or allow debris to enter connector contacts. Secure the following connectors to their respective terminals (Fig. 11D): A. Secure the 4-pin DPS connector. B.
Page 17
IN100 Cylindrical Lock 11 Installation of Inside Component Assembly (Controller) 1. Insert top tabs of controller into slots on mounting plate (Fig. 12). 2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate. CAUTION: To avoid possible damage to board-to-board connectors, care should be taken when securing controller to mounting plate.
Page 18
IN100 Cylindrical Lock 13 Battery Installation 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly (Fig. 12). 2. After batteries are installed, there is a slight delay; then red and AA Batteries (6) green flash*, audible “beep” and lock motor will cycle. *See Section 8 - LED Indications for more information Fig.
IN100 Cylindrical Lock Operational Check 1. Insert key into cylinder and rotate (Fig. 14A). There should be no friction against lock case, wire harness or any other obstructions. 2. Check that the key retracts the latch. The key should rotate freely. 3.
Page 20
IN100 Cylindrical Lock LED Indications The communication hub has a single LED. It supports an optical scheme of red, green and yellow. The indication scheme is described by the figures below: Communication Hub LED indications Figure 1. Communication hub normal 2 sec.
IN100 Cylindrical Lock Lock LED indications The lock has three LEDs. They support an optical scheme with red, yellow and green. The indication scheme is described by the figures below: Figure 4. Lock normal operation LED indication EAC response Enter PIN Card + PIN access time One yellow flash after card, two...
Page 22
IN100 Cylindrical Lock Lock Self-Test LED indication After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as described by the figures below. LED indication after power up/replacement of the battery 8.3.1 Battery not fully charged Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at the...