contains the data concerning the analogical inputs

Analog Output

contains the data concerning the analogical outputs

Digital Input

contains the data concerning the digital inputs

Digital Output

contains the data concerning the digital outputs
General
contains the data concerning the general measurements
Info
contains the information concerning module
N.B. In function of the type of unit that they represent, the tables can also contain data.
Let's Analyze the module related to the standard telemetry card: it contains: 24
analogical inputs (8+16) and 8 relay outputs; therefore data will be found only in the
Analog Input and Digital Output tables.
Similarly, for the PTXLCD (which has 39 analogical inputs, 2 analogical outputs, 8
digital inputs, 29 digital outputs, 8 general measurements), data will be found in all
the tables.
All the tables (except Info and Alarm Name) have the same structure:
For example:
The first analogical input of the telemetry card is composed in the following way:
Key
ID Measure
Display Order
User Manual
Name of area
Type of data
Key
Numerical
ID Measure
Numerical
Display Order
Numerical
Enable Input
Yes/No
Enable Display
Yes/No
Name
Text
Measure Unit
Text
Conversion Type
Text
End Scale
Numerical
Start Scale
Numerical
Max
Numerical
Nominal
Numerical
Min
Numerical
Format
Text
Input Mask
Text
Resolution ADC
Numerical
Type
Numerical
Text for Max
Text
Text for Min
Text
0
0
1
Rev. 1.0 - 17/01/03
Description
Univocal identification key
Identification of the measurement
Ordering displayed data
Enable input
Enable display
Measurement Name
Measurement Unit
Type of conversion
End scale
Start scale
Maximum value
Nominal value
Minimum value (offset)
Displaying Format
Input Mask
Resolution ADC converter
Type of measurement
Text to be displayed when maximum value is reached
Text to be displayed when minimum value is reached
Number of the measurement
Position in the order display
It is possible to enter values (not for the inputs)
SCM-TLC