7.3.5 Description of general alarms connector PIN
This section deals with the connector used by the device for the triggering of the
general RVR alarms (settable via the "TELECON" program).
This connector refers to the last telemetry card inside the machine.
7.3.5.1
Digital/analog input
Type: DB25 female
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26 / 50
GND
Alarm custom 1 "MAINS" (jumper pos.1 inserted on telemetry card)
Alarm custom 3 "AUDIO EXT" (jumper pos.3 inserted on telemetry card)
Alarm custom 5 "CONT GROU" (jumper pos.5 inserted on telemetry card)
Alarm custom 7 "OPEN" (jumper pos.7 inserted on telemetry card)
GND
GND
GND
Alarm custom 10 "ALARM 12" (jumper pos.10 inserted on telemetry card)
Spare Input
Spare Input
Spare Input
GND
GND
Alarm custom 2 "USER" (jumper pos.2 inserted on telemetry card)
Alarm custom 4 "LINK SAT" (jumper pos.4 inserted on telemetry card)
Alarm custom 6 "FUEL" (jumper pos.6 inserted on telemetry card)
Alarm custom 8 "ALARM 10" (jumper pos.10 inserted on telemetry card)
GND
GND
Alarm custom 9 "ALARM 11" (jumper pos.9 inserted on telemetry card)
Spare Input
Spare Input
Spare Input
GND
Rev. 1.0 - 05/05/03