TLC2000
7.2.3 Rly Output
This connector makes the contacts of 8 bistable relay switches available in output.
The figure shows a diagram of the relay home or Off position.
The maximum current which can be passed through the contacts is 500mA at 24V.
The contacts of the relay switches of this connector are used to command the
switching on and off of TXs.
The commands to switch on or off for the EXCiters , and for the Power Amplifiers are
given in different way. In On/Off mode the command acts on two particular inputs of
the power amplifier (one for the On and one for the Off) closing for approx. 0.5 seconds
two contacts of the shunter.
22 / 50
Numero pin
1 (C), 14 (NC), 2 (NO)
15 (C), 3 (NC), 16 (NO)
4 (C), 17 (NC), 5 (NO)
18 (C), 6 (NC), 19 (NO)
7 (C), 20 (NC), 8 (NO)
21 (C), 9 (NC), 22 (NO)
10 (C), 23 (NC), 11 (NO)
24 (C), 12 (NC), 25 (NO)
13
Rev. 1.0 - 05/05/03
Relay
Modo On/Off
1
Accensione TX
2
Spegnimento TX
3
Accensione 1
4
Spegnimento 1
5
Accensione 2
6
Spegnimento 2
7
Accensione 3
8
Spegnimento 3
Massa
User Manual