11.6.2 Balanced Analog Input
Place in ON position the Dip-switches 5 and 6 of SW2.
Verify that moving RV1 it modifies the reading of the analogic instrument called
"Balanced Analog input # 1" regarding the first analogic input of the telemetry to
which is connected the card.
Place in OFF position the Dip-switches 5 and 6 of SW2.
Remember to supply to the test card the voltage of 12 V, that can be continuous or
alternated, necessary to its operation and to connect well the 25 poles cables between
the same connectors.
11.6.3 Digital/Analog Input
Place in ON position the Dip-switch 4 of SW2 that will have to remain inserted for
all the Test duration.
Place in ON the Dip-switch 1 of SW2 and verify that moving the switch SW1 it
modifies the reading of the first digital input, correspondent to Type 8= analogic 9
of the telemetry card table to which is connected the card and the LED called
"Digital Input # 1" is illuminated.
Place in OFF position the Dip-switch 1 of SW2.