Basic Validator Setup

Unit Positioning
The validator must be positioned so that the scanning beam covers
the entire area containing the bar codes, including the area
required for quiet zones. The validator can be moved along the
lower bracket and aligned with any of the inscribed hash marks,
depending on the size of the labels printed and the positioning of
the bar codes on those labels. In addition, the beam width can be
moved horizontally to the left or right (see "Shifting The Scanning
Beam" on page 33).
If a bar code is completely outside of the scanning area, straddles
an edge, or does not pass completely under the scanning beam,
the validator interprets it as a missing bar code and generates error
conditions.
Validator Front Panel
The front panel of the validator has the following controls and
indicators:

Operation

POWER: Indicates the validator is at full power.
CALIBRATION: Flashes when the validator is in calibration
mode. See page 34 for calibration instructions.
READ: Flashes when the validator is reading a bar code.
1 and 2: Used for maintenance purposes only.
RESET: This button is used in the calibration procedure and
possible troubleshooting situations. Except in these specific
circumstances, the RESET button should not be used.