Chapter 1
Adjust The Scanning Beam
Summary Of Scanning Beam Adjustment
To Move Beam
Down
Tighten top left
Tighten both bottom
screw
screws
or
or
Loosen both
Loosen top left screw
bottom screws
NOTE: If the printer does not have a tear bar with notches at the
Figure 15. Adjusting the Center of the Scanning Beam
32
To Move Beam
To Rotate Beam
Up
Loosen bottom
right screw
or
Tighten bottom
left screw
ends, adjust the scanning beam so that the center of the
beam is approximately 0.06 inches (1.52 mm) from the
lower edge as shown in Figure 15.
0.06 inches
(1.52 mm)
To Rotate Beam
Clockwise
Counterclockwise
Loosen bottom left
screw
or
Tighten bottom
right screw