CALIBRATION Light
Calibration Bar Code Card
Figure 16. Calibrating the Validator
7. The scanning beam should turn off for a few seconds then back
on, and the CALIBRATION light should turn off. This indicates a
successful calibration.
NOTE: If the scanning beam does not turn back on and/or the
calibration light is still on or flashing, the calibration has
failed. In this case, refer to Table 2 on page 34 to repeat
the calibration procedure or to reset the validator settings
back to factory default.
8. Once you have a successful calibration, remove the calibration
bar code card.
9. Close the pivoting deck and rotate the deck lock lever fully
counterclockwise.
10. Close the media cover.