Idrac Settings Utility; Entering The Idrac Settings Utility - Dell PowerEdge R930 Owner's Manual

Hide thumbs Also See for PowerEdge R930:
Table of Contents

Advertisement

Option
Description
Asset Tag
Specifies the asset tag and enables you to modify it for security and tracking purposes.
Keyboard NumLock Enables you to set whether the system boots with the NumLock enabled or disabled. This option is set to On by
default.
F1/F2 Prompt on
Enables or disables the F1/F2 prompt on error. This option is set to Enabled by default. The F1/F2 prompt also
Error
includes keyboard errors.
Load Legacy Video
Enables you to determine whether the system BIOS loads the legacy video (INT 10H) option ROM from the video
Option ROM
controller. Selecting Enabled in the operating system does not support UEFI video output standards. This field is
available only for UEFI boot mode. You cannot set the option to Enabled if UEFI Secure Boot mode is enabled.
In-System
Enables or disables In-System Characterization. This option is set to Disabled by default. The two other options
Characterization
are Enabled and Enabled - No Reboot.
When enabled, In-System Characterization (ISC) executes during POST upon detecting relevant change(s) in
system configuration to optimize system power and performance. ISC takes about 20 seconds to execute, and
system reset is needed for ISC results to be applied. The Enabled - No Reboot option executes ISC and continues
without applying ISC results until the next time system reset occurs. The Enabled option executes ISC and forces
an immediate system reset so that ISC results can be applied. It takes the system longer to be ready due to the
forced system reset. When disabled, ISC does not execute.
Related links
Miscellaneous Settings
Viewing Miscellaneous Settings

iDRAC Settings utility

The iDRAC settings utility is an interface to set up and configure the iDRAC parameters by using UEFI. You can enable or disable various
iDRAC parameters by using the iDRAC settings utility.
NOTE:
Accessing some of the features on the iDRAC settings utility needs the iDRAC Enterprise License upgrade.
For more information about using iDRAC, see Dell Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals.
Related links
Device Settings
System BIOS

Entering the iDRAC Settings utility

Changing the thermal settings
Entering the iDRAC Settings utility
1
Turn on or restart the managed system.
2
Press F2 during Power-on Self-test (POST).
3
On the System Setup Main Menu page, click iDRAC Settings.
The iDRAC Settings screen is displayed.
Related links
iDRAC Settings utility
NOTE:
This option does not apply to 84-key keyboards.
NOTE:
The default setting for In-System Characterization is subject to change in future BIOS releases.