6.8 Hydraulic Check

When the machine is shipped, the breather cap should be replaced with a 3/4 NPT plug. This is how
the machine is shipped from the factory. Before the machine can be run for the first time the NPT
plug needs to be replaced with the breather cap. Access the plug behind the small cover on the
hydraulic power unit cover behind the machine.
The hydraulic reservoir is filled with 15 gallons of grade #46 hydraulic oil at the factory. The fluid level
should be checked before operation, and periodically during normal operation. The reservoir is
located behind the cutter, beneath the table (Figure 10). The hydraulic tank has a breather cap that