8.0 Operation
8.12.2.4 Knife Count
The knife count parameter allows the operator to reset the knife alarm and the lube alarm. The knife
alarm displays a message to remind the operator to change the knife. The lube alarm displays a
message to remind the operator to have the machine lubricated. The lube alarm will also display the
name and phone number of the Challenge dealer from which the machine was purchased.
There are three functions within the knife count parameter: Clear Count, Knife Alarm, and Clear
Lube. Select the desired function and press ENTER. See the following descriptions for an
explanation of each function.
Select Clear count to reset the knife counter when a knife change has been performed.
Select Knife Alarm to enter or change the knife stroke alarm value. When this value is reached, the
display will alert you to change the knife and reset the knife counter. Knife alarm values for the
Champion XG are factory set at 2,500 cuts. However, you may want to change this value based on
your specific machine applications. See the Knife section for help in choosing a knife alarm value for
your machine.
Select Clear lube to reset the lube alarm after performing the lubrication requirements as shown in
the Lubrication section of this manual. NOTE: The alarm will activate after 2,500 cuts. This value is
set at the factory and cannot be changed.
8.12.2.5 Machine Count
The number displayed is the total number of cuts made by the machine.

8.12.3 Diagnostic

-------------------------------
The diagnostic area can be very helpful in locating a problem in the event of a machine malfunction.
Use the up and down arrow keys to toggle to the desired selection, and press ENTER. See the
following descriptions for an explanation of each.
8.12.3.1 Error Code
The Error Code function simply recalls the last five error messages that were displayed. This can be
very useful in cases when the malfunction cannot be reproduced in the presence of the service
technician.
30
Clamp
Pressure
| | | 14 | | |
C) Up
D) Down
5.070
in
DIAGNOSTIC
Error Code
Sensor Data
Clear Memory
Adjust Clamp
Select and press enter
A) Maint
G) Send
F) Job
H) Exit