Rem Measurement - Sokkia CX-101 Service Manual

Compact x-ellence station cx series
Hide thumbs Also See for CX-101:
Table of Contents

Advertisement

12. DISTANCE MEASUREMENT

12.6 REM Measurement

An REM measurement is a function used to measure the height to a point where
a target cannot be directly installed such as power lines, overhead cables and
bridges, etc.
The height of the target is calculated using the following formula.
Ht = h1 + h2
h2 = S sin θ z1 x cot θ z2 - S cos θ z1
Zenith
Zenith
• The items displayed as <Null> in the coordinate data are excluded from the
calculation (Null is different from 0).
PROCEDURE
1. Set the target directly under or
directly over the object and
measure the target height with a
tape measure etc.
2. After inputting the target height,
accurately sight the target.
"
"
Press [MEAS] in page 1 of Obs
Mode to carry out measurement.
58