3D Touch Probes
9.6
Measuring
Tools with the lT 120 Touch Probe
Calibrating
the lT 120
* Before calibrating tha touch prrab;e, yau must enter the exact length and radius of the calibrating tmt into the
tcml table TOQC.1".
* The posttim of thle 'ITT 120 within the machine work@ space must be defined by setting th@ machine
parmtjtsrs 658O.Q to 6580.2 {.WB page 't2-5).
The lT 120 is calibrated
automatically
with the measuring
cycle TCH
PROBE 30. The TNC also determines
the center misalignment
of the
calibrating
tool. For this operation,
the spindle is rotated
by 180" when
the first half of the calibration
cycle has been executed.
The calibrating
tool must be a perfectly
cylindrical
part, such as a cylindrical
pin. The
resulting
calibration
values are stored in the TNC memory
and are
accounted
for during subsequent
tool measurement.
To program
TCH PROBE 30.0:
Select the probing functions.
1 W)
/
Select the calibration
cycle.
Enter the position in the tool axis at which there is no danger of
collision with the workpiece
or fixtures.
Resulting
NC blocks:
TOOL CALL 1 Z
TCH
PROBE
30.0 CALIBRATE
77
TCH
PROBE
30.1 HEIGHT
+90
TNC 370
9-33