9
3D Touch
Probes
-
9.6
Measuring
Tools with the lT 120 Touch Probe
4
MP6507=1:
The measuring
tolerance
depends
on the size of the tool
radius. This prevents the probe feed rate from being
decreased
to zero when a tool with a large radius is being
measured.
The TNC adjusts the measuring
tolerance
as
4
follows:
Tooi radius
Messurlng
taler8knce
Up to 30 mm
MP6510
30 to 60 mm
2 . MP6510
60 to 90 mm
3
l
MP6510
90to120mm
4
l
MP6510
MP6507=2:
The probe feed rate remains
constant while the error of
measurement
is increased
linearly with the size of the tool
radius:
Measuring
tolerance
=
r
l
5yL6P6; '
where
r=
Tool radius [mm]
MP6510
=
Maximum
permissible
error of measurement
Displaying
the results
of tool measurement
In the program
run modes of operation,
you can select the TEXT / TOOL
PROBE STATUS
screen layout. The TNC then displays the program
text
in the left and the measuring
results in the right screen window
(see page
I-4). The measuring
results that exceed the permissible
wear tolerance
are marked with an asterisk (*I, and those that exceed the permissible
breakage
tolerance
are identified
with the letter B.