HEIDENHAIN TNC 370 User Manual page 264

Conversational programming
Table of Contents

Advertisement

9
3D Touch
Probes
9.2
Touch
Probe Cycles in the MANUAL
and ELECTRONIC
HANDWHEEL
Operating
Modes
To calibrate
the effective
radius
Position
the ball tip in the bore hole of the ring gauge.
Fig. 9.6:
Calibrating the touch probe radius
Select the calibration
function for the ball-tip radius.
Select
RADIUS
RING GAUGE.
Enter the radius of the ring gauge, for example
5 mm
,
The 3D touch probe contacts one position
on the bore for each axis
direction.
-
J
Displaying
calibration
values
The TNC 370 stores the effective length and radius of the 3D touch
probe for use whenever
the touch probe is needed
again. The stored
values are displayed
the next time the calibration
function
is called.
4
4
-/
9-6
TNC 370
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents