9
3D Touch
Probes
d
9.3
Measuring
Workpieces
with a 3D Touch Probe
Measuring
with the 3D touch
probe
during
program
run
The 3D touch probe can measure
positions
on a workpiece
during
program
run.
Applications:
l
Measuring
differences
in the height of cast surfaces
l
Checking
tolerances
during
machining
To activate the touch
probe,
press
the
TOUCH
PROBE key. You pre-
position
the probe, which
then automatically
probes the specified
position.
The coordinate
measured
for the probe point is stored
in a Q
parameter.
The control
interrupts
the probing
process if the probe is not deflected
within
a certain
range (range selected
with MP 6130). Upon contact, the
position
coordinates
of the probe are stored in the parameter
0115 to
0119.
The values in these parameters
do not include the stylus length
Fig. 9.15:
Dimensions
to be measured
or radius.
d
J
To program
the use of a touch
probe
pEgbf
E)
-l
Select the touch probe function.
L
J
t
1
PARAm=
NUMBER
FURRESULT?
i
i
e.g.0
EIy
Enter the number
of the Q parameter
to which
the coordinate
is to
be assigned,
for example
05.
L
J
,
PRoBIlyG
AxH.@ROBING
IDIRECmON?
i
e.g.
i-'
X
>
Enter the probing
axis for the coordinate,
for example
X.
Select and confirm the probing
direction.
e.g. 0
Ey
4
-
4
4
d
9-18
TNC 370
-

Hide quick links: