HEIDENHAIN TNC 370 User Manual page 263

Conversational programming
Table of Contents

Advertisement

9
3D Touch
Probes
L/
-
9.2
Touch
Probe Cycles in the MANUAL
and ELECTRONIC
HANDWHEEL
Operating
Modes
Calibrating
a triggering
3D touch
probe
The touch probe system must be calibrated
l
for commissioning
l
after a stylus breaks
l
when the stylus is changed
l
when the probe feed rate is changed
l
in case of irregularities,
such as those
resulting
from machine
heating.
During calibration,
the control finds the "effective"
length of the stylus
and the "effective" radius of the ball tip. To calibrate
the 3D touch probe,
clamp a ring gauge with known
height and known
internal radius to the
machine
table.
To calibrate
the effective
length
Set the datum in the tool axis such that for the machine
tool table, Z=O.
Fig. 9.5:
Calibrating
the touch
probe
length
Select the calibration
function
for the touch probe length.
If necessary,
enter the tool axis, for example
Z.
Move the highlight
to DATUM.
Enter the height of the ring gauge, for example
5 mm
e.g.1
2
)
0
e.g.
0
Move the touch probe to a position
just above the ring gauge.
I
0-o
or
If necessary,
change the displayed
traverse
direction.
\
The 3D touch probe contacts
the upper surface of the ring gauge.
1
TNC 370
9-5