HEIDENHAIN TNC 370 User Manual page 280

Conversational programming
Table of Contents

Advertisement

9
3D Touch
Probes
9.4
Digitizing
with a Triggering
30 Touch Probe (Optional)
Defining
the digitizing
range
The digitizing
range is defined
in the RANGE cycle. The model to be
scanned
must lie within
this range. In this cycle you also enter the name
of the file for the digitized
data, as well as a clearance
height for pre-
positioning
the touch probe.
1
MiN
Fig. 9.16:
Clearance height and digitizing
range
Input
data
l
PGM NAME
OF DIGITIZED
DATA
Name of the file in which the digitized
data is to be stored
.
MIN POINT OF RANGE
Lowest
coordinates
in the range to be digitized
l
MAX
POINT OF RANGE
Highest coordinates
in the range to be digitized
. CLEARANCE
HEIGHT
Position
in probe axis at which the stylus cannot collide with the model
Setting
the scanning
range
Select probing
functions.
- ,
Select RANGE digitizing
cycle.
Enter the name of the file in which the digitizing
data should be stored and confirm with ENT.
I4
TCH PROBE AXIS ?
Enter the touch probe axis and confirm with ENT.
2
9-22
TNC 370

Hide quick links: